The patient, an 81-year-old woman, was hospitalized in the Department of Geriatric Trauma and Orthopedics of Jishuitan Hospital because of a fall on her right hip. In particular, the patient was diagnosed with a right femoral neck fracture 7 years ago due to his right hip landing after a fall. This fracture is also known as the "last fracture of life" in the elderly, and the mortality and disability after the fracture are high. The rate is very high. The old man underwent artificial femoral head replacement at that time, and he quickly recovered to a normal life after the operation. He walked freely for 7 years. Unfortunately, the patient suffered a second fall injury that resulted in a periprosthetic fracture of the right femur, which was more complicated, more difficult to treat, and more operative than the previous one.

Door het uitzoeken van oudere patiënten met heupfracturen die in het verleden werden gediagnosticeerd en behandeld door de afdeling Trauma en Orthopedie van het Beijing Jishuitan Hospital, ontdekte het team van vice-president Wu Xinbao en hoofdarts Yang Minghui dat met de toename van oudere patiënten met heupfracturen , is ook het aantal kunstmatige heupprothesen geleidelijk toegenomen. Dergelijke patiënten lopen ook een hoog risico op verder valletsel, wat betekent dat periprothetische femurfracturen ook bij oudere volwassenen zullen toenemen. De behandeling van dergelijke oudere femurperiprothetische fracturen is altijd een moeilijk probleem geweest voor orthopedische artsen. Bij de behandeling moet rekening worden gehouden met drie aspecten van fractuur, prothese en botmassa. Het maakt niet uit welk behandelplan wordt aangenomen, de behandeling is erg moeilijk.
For this elderly man with secondary fragility orthopedics, the treatment team considered that most of the current periprosthetic fracture plates do not match the shape of the patient's proximal femur and cannot be well attached to the surface of the proximal femur, which is likely to cause metal objects to irritate the surrounding soft tissue. It will affect the recovery of limb function after surgery. In addition, the presence of the prosthesis prevents the placement of screws at the proximal end of the plate, and there is no dedicated channel for cable cerclage on the plate, resulting in unstable fracture fixation and failure of the internal fixator in the long-term. It would be a disastrous outcome for the elderly with subfragile fractures.
Therefore, through a comprehensive analysis of the patient's condition, the treatment team decided to adopt the 3D printing technology that is currently at the forefront of orthopedic treatment. The traditional 3D printing custom steel plate is just a 3D printing of the femur model, and then the customized steel plate is processed by the machine tool. Through the medical-engineering interaction system of AK Medical, the RD engineer team closely cooperates with the team of Professor Wu Xinbao. According to the image data of the patient's affected limb, a specially designed The anatomical femoral periprosthetic plate is made by custom-made metal 3D printing technology. The customized plate uses an innovative design. Morphologically, the hook-like structure at the proximal end of the plate can fit perfectly with the patient's major trochanter. The plate has specially made a channel for the cerclage cable in the femoral prosthesis segment, which makes the operation easier. It is simple and convenient, and the plate is designed with 4 screw holes in the distal part of the prosthesis for the placement of bicortical screws. The stable fracture fixation ability of the whole customized plate system, the anatomical shape design for easy reduction and fixation, and the precise functions of the trochanteric hook and the proximal cerclage channel form a fracture internal fixation system that integrates three major advantages. , so as to avoid the deficiencies of traditional internal fixators, and at the same time take into account the needs of periprosthetic fractures, prosthesis and insufficient bone mass, increase the strength of internal fixation for fractures, and more reliably ensure the clinical treatment goal of fracture healing.


Na een gedetailleerde preoperatieve planning door het behandelteam, heeft het team op 12 januari 2022 met succes de reductie en fixatie van de fractuur volgens het chirurgische ontwerp voltooid. De operatie duurde 1 uur en 45 minuten en het bloedverlies was 400ml. Postoperatieve beelden toonden aan dat de fractuur anatomisch was verminderd, de op maat gemaakte -plaat correct was gepositioneerd en de plaatsing van de kabelcerclage en de schroef ideaal waren, waarmee de chirurgische doelen van preoperatieve planning perfect werden bereikt.





Voor oudere patiënten met osteoporose en speciale morfologie van de fractuurplaats, vooral voor patiënten met fracturen die optreden rond kunstmatige gewrichtsprothesen, zijn een goede reductie en stevige fixatie van de fractuur de voorwaarden voor fractuurgenezing en herstel van de functie van het aangedane ledemaat. Voor patiënten met een abnormale anatomie van de fractuurplaats kunnen conventionele stalen platen geen perfecte anatomische hechting aan de structuur van de fractuurplaats bereiken. Het gebruik van op maat gemaakte prothesen kan een gemakkelijke fractuurvermindering bereiken, het postoperatieve gevoel van een vreemd lichaam verminderen en de fractuurfixatie verbeteren. betrouwbaar.
At present, "3D printing customized surgical technology" has become one of the effective treatment methods for specific groups of people, which can greatly reduce the complications caused by insufficient traditional treatment methods, and can provide patients with more effective clinical treatment effects. However, this technology also has shortcomings such as a slightly longer waiting time for printing and a lack of special surgical tools, which needs to be further improved in clinical practice.